SE25K EXTENDED POWER INVERTER

Specifically designed to work with power optimisers

• Superior efficiency (97.6%))
• Small, lightweight and easy to install
• Built-in module-level monitoring
• Internet connection through Ethernet or Wireless
• IP65 – Outdoor and indoor installation
• Fixed voltage inverter, DC/AC conversion only
• Optional integrated DC Safety Unit – eliminates the need for external DC isolators (SE25K and SE27.6K only)
• Optional DC surge protection and DC fuses (SE25K and SE27.6K only)

SE25K
Maximum DC Power (Module STC) 33750 W
Transformer-less, Ungrounded Yes
Nom. DC Input Voltage DC to Gnd 375
Max. Input Voltage DC to Gnd 415
Nom. DC Input Voltage DC+ to DC- 750
Max. Input Voltage DC+ to DC- 830 Vdc
Maximum Input Current 37 Adc
Reverse-Polarity Protection Yes Vdc
Ground-Fault Isolation Detection 700kΩ
Sensitivity
Maximum Inverter Efficiency 98
European Weighted Efficiency 98 %
Nighttime Power Consumption < 4 W
SE25K
Rated AC Power Output 25000 VA
Maximum AC Power Output 25000 VA
AC Output Voltage – Line to Line / Line to Neutral (Nominal) 400 / 230 Vac
AC Output Voltage – Line to Neutral Range 184 – 264.5 Vac
AC Frequency 50/60 ± 5 Hz
Maximum Continuous Output Current (per Phase) 38 A
Residual Current Detector / Residual Current Step Detector 300 / 30 mA
Grids Supported – Three Phase 3 / N / PE (WYE with Neutral);
230 / 400
V
Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes
Supported Communication Interfaces* RS485, Ethernet, Zigbee (optional), Wi-Fi (optional), Built-in GSM (optional)

* Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads

2-pole Disconnection 1000V / 40A
DC Surge Protection Type II, field replaceable
DC Fuses on Plus & Minus Optional, 20A
Compliance UTE-C15-712-1
Safety IEC-62103 (EN50178), IEC-62109, AS-3100
Grid Connection Standards¹ VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016², BDEW²
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12,
RoHS Yes

¹ For all standards refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads

² Model SE27.6K only

AC Output Cable Gland – diameter 15-21 mm
DC Input 3 MC4 pairs
DC Input with Safety Unit Gland outer diameter 5-10 mm
Dim with Safety Unit (HxWxD) 775 x 315 x 260 mm
Weight 45 kg
Weight with Safety Unit 48 kg
Operating Temp Range – 20 – +60 (M40 version – 40 – +60) ˚C
Cooling Fan (user replaceable)
Noise < 55 dBA
Protection Rating IP65 – Outdoor and Indoor
Bracket Mounted (Bracket Provided)