STOREDGE INVERTER SE6000 (Australia)

OUTPUT – AC (LOADS/GRID) SE6000
Rated AC Power Output 6000 VA
Max AC Power Output 6000 VA
AC Output Voltage (Nominal) 220 /230 Vac
AC Output Voltage Range 184 – 264.5 Vac
AC Frequency 50 / 60 ± 5 Hz
Maximum Continuous Output Current 27 A
Residual Current Detector / Residual Current Step Detector 300 /30 mA
Utility Monitoring, Overloading Protection, Country Configurable Thresholds Yes
Charge Battery from AC (if Allowed) Yes
THD <5 %
Power factor with rated power >0.99 (configurable; 0.9 leading to 0.9 lagging)
Typical Nighttime Power Consumption <5 W
OUTPUT – AC (BACKUP POWER)(1) SE6000
Rated AC Power Output 4985(2) VA
Max AC Power Output – Surge 7300 VA
AC Output Voltage (Nominal) 220 /230 Vac
AC Output Voltage Range 184 – 264.5 Vac
AC Frequency 50 / 60 ± 5 Hz
Maximum Continuous Output Current 22 A
AC Breaker Yes
THD <3 %
Power factor with rated power 0.2 leading to 0.2 lagging
Automatic switchover time <5 sec
Typical Nighttime Power Consumption <5 W
(1) Not designed for standalone applications and requires AC for commissioning

(2) The rated AC power output is the minimum between 4985VA and the battery continuous peak power

INPUT – DC (PV and BATTERY) SE6000
Transformer-less, Ungrounded Yes
Max Input Voltage 500 Vdc
Nom DC Input Voltage 400 Vdc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection  600kΩ Sensitivity
Maximum Inverter Efficiency 97.6 %
European Weighted Efficiency 97.4  %
INPUT – DC (PV) SE6000
Maximum DC Power (STC) 8100  W
Max Input Current (4) 23 Adc
2-pole Disconnection Yes
INPUT – DC (BATTERY) SE6000
Continuous Peak Power 3300  W
Number of Batteries per Inverter(3) Up to 2, for double capacity
Max Input Current 8.5  Adc
2-pole Disconnection Yes
DC Fuses on Plus and Minus 12A (field replaceable)
(3) For two batteries for double power contact SolarEdge technical support
Supported Communication Interfaces RS485 for battery, RS485, Ethernet, ZigBee (optional), Wi-Fi (optional)
Battery Power Supply Yes, 12V / 53W
Integrated AC, DC and Communication Connection Unit Yes
AC Disconnect Yes
Manual Inverter Bypass Switch Yes
DC Voltage Rapid Shutdown (PV and Battery) Yes, according to VDE 2100-712 (pending)